Handicare 1100 · straight stairs

Handicare 1100 problems and what the display means

Handicare 1100 problems usually show as a single character on the lift's diagnostic display, which Handicare's TechTool says sits under a grey cover behind the seat. A 0 or a dash means something an owner can put right (the key, the stop button, an armrest or the seat), a 2 means it is not charging, and letters such as d, o and Y mean ring Handicare. Below are Handicare's own five checks, every code from its manual, its reset and its charging rules.

Last checked: , against the makers' own documents Not affiliated with any manufacturer

Handicare's five checks first

The current 1100 manual (2023 edition) has no code table, but it does give owners a checklist for any malfunction (Handicare 1100 manual, 2023p.3). In this guide's words:

  1. The seat. Is it in the right position, turned to face forward and locked, before you set off?
  2. Seat and armrests. Are both folded down?
  3. The key. Is the lift switched on at the key switch? It turns a quarter turn clockwise.
  4. The emergency stop. Has it been pressed? One press releases it; on some lifts it releases by turning.
  5. The seatbelt. Is it fastened?

For anything else, the manual says to contact your supplier, and to have the lift's serial number ready: it is on a label on the power pack under the seat.

Every 1100 display code

The code table is in the earlier, full edition of the 1100 manual (AA20759_15, dated February 2020), which Handicare still hosts on TechTool although its 1100 page now links the 2023 edition (Handicare 1100 manual, 2020pp.26-28). Where TechTool's 1100 pages add a check, the row says so.

Handicare 1100 display codes, from the 2020 full manual and Handicare TechTool
Shows What the maker says it means What the maker lets you check When it needs an engineer Where it says so
- One symbol, two causes: the lift is charging but will not drive because an armrest is folded up, or the seat is swivelled and not locked. Fold both armrests fully down, and turn the seat back with the handle under it until it clicks into place. Both Handicare code pages say: if the action shown does not help, call Handicare, and write the code down first. Handicare 1100 manualpp.20, 26
0 Also two causes: the key switch is off, or the emergency stop button has been pressed (its light is on). Turn the key a quarter turn clockwise; if the stop button is lit, press it once and its light goes out. Both Handicare code pages say: if the action shown does not help, call Handicare, and write the code down first. Handicare 1100 manualpp.19, 26
1 The batteries need charging. Send the lift to a charge point, as the manual's picture for this code shows. Both Handicare code pages say: if the action shown does not help, call Handicare, and write the code down first. Handicare 1100 manualp.26
2 Off charge. The manual adds that the lift beeps for 40 seconds and the batteries are not recharging, possibly because the plug is out of its socket. Put the lift's plug back in its socket; TechTool adds that every power switch should be on. Both Handicare code pages say: if the action shown does not help, call Handicare, and write the code down first. Handicare 1100 manualpp.21, 26
3 The limit at the top end of the track has been triggered. No owner check given. No owner action is printed. If the lift will not move away from the top, call Handicare. Handicare 1100 manualp.26
4 The safety edge facing up the stairs has been pressed, so the lift will travel one way only. Drive the lift in the opposite direction and take away whatever is in its path. Both Handicare code pages say: if the action shown does not help, call Handicare, and write the code down first. Handicare 1100 manualpp.22, 26
5 The limit at the bottom end of the track has been triggered. No owner check given. No owner action is printed. If it will not move away from the bottom, call Handicare. Handicare 1100 manualp.26
6 The safety edge facing down the stairs has been pressed; travel is allowed in one direction only. Reverse the lift and remove the obstacle from between the lift and the stairs. Both Handicare code pages say: if the action shown does not help, call Handicare, and write the code down first. Handicare 1100 manualpp.22, 26
7 The battery voltage is too low for a journey. Wait about 30 minutes before trying another ride. Both Handicare code pages say: if the action shown does not help, call Handicare, and write the code down first. Handicare 1100 manualpp.22, 27
8 The toggle is held and the lift is riding up. The current manual says the display shows 8 or 9 as the lift starts. No owner check given. Nothing to fix: the lift is doing what it should. Handicare 1100 manualp.27
9 The toggle is held and the lift is riding down. No owner check given. Nothing to fix: the lift is doing what it should. Handicare 1100 manualp.27
d A fault: the main power relay is not opening. No owner check given. The tile shows a telephone: call Handicare. Handicare 1100 manualp.27
L The manual files L under motor problems (L0 to L4) and pictures a heavy load on the seat; Handicare's TechTool says L means the lift is overloaded. Take weight off the lift (TechTool). Still showing: call Handicare. Handicare 1100 manualp.27
o The main control board has a memory problem. No owner check given. Telephone on the tile: call Handicare. Handicare 1100 manualp.27
blank A dark display is sleep mode. Move the armrest toggle, or press a button on a remote, to wake it. If it stays dark after that, call Handicare. Handicare 1100 manualp.27
self-test The display runs through its segments for about three seconds after the toggle is pushed: the lift is testing itself before it moves. No owner check given. Nothing to fix: the lift is doing what it should. Handicare 1100 manualp.27
Ir / rF An infrared (Ir) or radio (rF) remote control has been registered with the lift. No owner check given. Nothing to fix: the lift is doing what it should. Handicare 1100 manualp.27
FP The footplate has been operated. No owner check given. Nothing to fix: the lift is doing what it should. Handicare 1100 manualp.27
Y A hardware fault, with a second character (Y0, YF, YI, Yr, Yb or YbF) narrowing it down. No owner check given. Telephone on the tile: call Handicare and give the full code. Handicare 1100 manualp.28
8. / 9. A powered swivel seat is turning up (8.) or down (9.). No owner check given. Nothing to fix: the lift is doing what it should. Handicare 1100 manualp.28
SL / noSL Whether the lift has registered a slide track at the foot of the rail. No owner check given. Nothing to fix: the lift is doing what it should. Handicare 1100 manualp.28

Not charging, beeping, and the plug

If the 1100 beeps for 40 seconds and shows 2, its batteries are not recharging, and the manual's first suspect is the plug: put it back in the socket (Handicare 1100 manual, 2020p.21). TechTool adds that every power switch should be on. The manual's reminders page says never to take the lift's plug out of the wall socket at all. A 7 is the next stage: the battery is too low to ride, and the manual's advice is to wait about 30 minutes before trying again.

There is one time the current manual asks you to switch the lift off. On lifts with the optional on/off switch, if the power fails across the house, switch the lift's power off to stop its batteries draining (Handicare 1100 manual, 2023p.3). Remember to switch it back on when the power returns. After a power cut has what other makers say.

Handicare 1100 battery replacement

Neither 1100 manual tells owners how to change the lift's own batteries, and neither treats it as an owner's job: the code pages end with "call Handicare". Handicare's guarantee terms in the 2020 manual exclude batteries. The useful owner habits are the ones above: keep it plugged in, keep it on charge, and note how long a full charge lasts if you think the batteries are failing. Battery replacement sets out what each maker says.

How to reset a Handicare 1100

Handicare's TechTool asks first when the lift was installed. For an 1100 installed before May 2024, its reset uses the key switch under the arm: turn the key off, wait 30 seconds, turn it back on (Handicare TechTool, 1100web page). For one installed after May 2024, TechTool's reset includes taking off a cover on the bottom of the lift to reach an on/off switch; this guide does not relay steps that open a cover, so ask Handicare or an engineer to talk you through it. Neither manual prints a reset of its own. How to reset a stair lift compares the makers.

Stopping and restarting

The 1100 moves only while you hold the toggle. Let go and it stops; the current manual says to wait three seconds, then push and hold the toggle again in the direction you want until you reach the landing (Handicare 1100 manual, 2023p.4). As the toggle is pushed, the display shows 8 going up or 9 going down, and the 2020 manual describes a short self-test of about three seconds before it moves. A manual hinged rail that has been folded will stop the lift when it reaches it, though it can still ride upwards.

Stuck with someone on it

If they are hurt or cannot get off safely, call 999. Handicare recommends keeping a phone or other communication device to hand when using the lift. Stuck on the stairs has each maker's advice.

The remote control

Handicare's two sources read the remote's red light in opposite ways. The 2020 manual says that if the lift will not travel and the remote's light shines red when pressed, the remote's batteries are flat and should be replaced (Handicare 1100 manual, 2020p.21). TechTool asks whether the light is red and, if it is not, says to replace the batteries; if it is, it runs through the lift's own checks instead. Either way, fresh batteries fitted the right way round are the cheapest first step. The 1100 also shows Ir or rF when a remote has been paired with it. See remote not working.

Care that prevents faults

The 1100 drives along its rail by friction, and the current manual says in capitals not to put lubricant or grease on the rail. Vacuum the rail with a soft brush, wipe off dirt with a slightly damp cloth, and use no cleaning products on it. Take the key out when you leave the lift. Everything beyond that, including the yearly service Handicare asks for, is an engineer's work.

The 1100's manuals are in the manual finder; the other Handicare models are on the Handicare page.

Where this comes from

Each meaning, check and number above is taken from the documents listed here, opened on the maker's own website. Page numbers in the text are the numbers printed in each manual. How the makers' documents are checked.

Get a stair lift repair quote

For when the maker's manual says it is a job for an engineer. Give the make, the model and what the lift shows or does. Replies come by email, so this is not the way to get help for someone stuck on a lift now.

After you press send

  1. SEO Dons Ltd, which publishes Stairlift Support, receives what you send.
  2. Someone reads the make, the model and the fault, and replies by email.
  3. There is no obligation: asking does not commit you to any repair.
Add the model and the exact code, light or beep (optional)

Stairlift Support is published by SEO Dons Ltd, which has no engineers and no link to any stair lift maker. Answers come by email. Someone stuck on a stair lift who is hurt or in danger needs 999, not this form. How details are used: privacy notice.

Get a stair lift repair quote