First: is the lift itself switched on?
A remote only tells the lift what to do; if the lift is off, nothing happens. Stannah's remote page says to check the power key is in and switched to on before anything else, because neither the lift nor the remotes work otherwise (Stannah remote pageweb page). Its 600 guide adds that the on/off switch must be on too. Acorn's 180 manual says the lift must be switched on, with the seat facing forward, before the remotes will work (Acorn 180 manualp.15). Handicare's TechTool runs through the same ground: the lift asleep, the key off, the emergency stop lit.
Batteries and lights, make by make
| Model | Battery | What the light tells you | Source |
|---|---|---|---|
| Stannah 600, 260, 420 | Three AA per remote; about a year with average use | Lights rotating: fine. On all the time: low. None: flat. With a hinged rail (260): flashing green means low | Stannah guidesp.19 |
| Acorn 130 | Replace yearly, Acorn recommends | Not described; the handset must point at an infrared sensor on the carriage | Acorn 130 manualpp.12, 21 |
| Acorn 180 | One 9 volt PP3; replace yearly | Not described | Acorn 180 manualp.15 |
| Handicare 1100 | Not stated | The 2020 manual: red when pressed means flat batteries. TechTool: no red light means replace the batteries | Handicare 1100 manualp.21 |
| Handicare 1000 | Not stated | The manual: red when pressed means flat batteries. TechTool: no light means replace them | TechTool 1000web page |
| Handicare Freecurve | Not stated | No light when pressed: flat batteries. Flashing twice a second: the lift is out of order, or stopped away from a charging station | Freecurve manualpp.23, 25 |
Changing the batteries
Changing a handset's batteries is the one battery job makers give to owners. Stannah's guides say to remove the screw, slide the battery cover down, open it and fit three new AA batteries; its remote page says to have three new ones ready, and that if the remote still does not work afterwards you should contact your local service branch. Acorn's 180 manual shows its PP3 battery cover sliding off the back of the handset, and warns that a battery fitted the wrong way round can damage the remote. Handicare's TechTool says simply to replace the batteries and make sure they are fitted correctly (Handicare TechTool, 1100web page). Acorn asks for old handset batteries to go to a recycling centre or a collection point in a shop.
When the batteries are fine
Acorn: interference and pairing
Acorn's handsets use infrared, and the 130 manual names two things that can upset them. Interference from outside sources can stop the lift part way, which Acorn calls a normal safety feature: release the button and press it again. And some low-energy light bulbs give off infrared light; if one is interfering, Acorn recommends changing it for a standard bulb (Acorn 130 manualp.21). The same page describes re-programming a handset that has lost its programming; because it involves pressing a safety edge on the carriage, this guide does not set it out. Follow Acorn's page exactly or ask an engineer.
Handicare: a reset, and the codes
For a 1000 whose remote has stopped but whose joystick still works, TechTool suggests switching the main power switch off for 10 to 15 seconds and back on. The 1100's display shows Ir or rF when a remote has been registered with it, and the 1000's shows C for an infrared address fault, which is one for Handicare.
Stannah: the wall controls
Stannah's remote calling controls stop the lift as soon as the arrow is released, and it will not start again for a few seconds; that pause is deliberate. Replacement or extra remotes come from your local service branch.
Still not working
If the lift runs from its own armrest control but no remote moves it, and new batteries have made no difference, the handset or the lift's receiver needs an engineer. If the lift does not run from the armrest either, the problem is not the remote: start with the switches and the code on the symptom finder, or the error code library. Brooks says its lifts come with two wireless remotes, and its site publishes no remote troubleshooting. The repair quote form at the foot of this page reaches SEO Dons Ltd, which replies by email.
Where this comes from
Each meaning, check and number above is taken from the documents listed here, opened on the maker's own website. Page numbers in the text are the numbers printed in each manual. How the makers' documents are checked.
- Stannah: Stairlift remote control troubleshooting
- Stannah: Model 600 Siena: Looking after your stairlift
- Stannah: Stannah 260 product support
- Acorn Stairlifts: Acorn Superglide 130 straight stairlift user manual (control board T700)
- Acorn Stairlifts: Acorn 180 curved stairlift user manual (T565)
- Handicare: Handicare 1100 user manual (earlier full edition, with the diagnostic codes)
- Handicare TechTool: Handicare 1100: what's the problem with your stairlift?
- Handicare TechTool: Handicare 1000: what's the problem with your stairlift?
- Handicare: Freecurve user manual (English edition)
- Brooks Stairlifts: Straight stairlift features