Power cuts

Stairlift not working after a power cut

A stairlift not working after a power cut has usually run its batteries down while the power was off, or been left switched off somewhere. Stannah, Acorn, Brooks and TKE all say their lifts keep running on batteries during a cut, for a while: Stannah says at least 15 to 20 trips up and down from a full charge, Acorn says several journeys. After that the lift stops until it has recharged. Here is what each maker says happens during a cut and what to check when the power comes back.

Last checked: , against the makers' own documents Published by SEO Dons Ltd

During a power cut

What each maker says its lifts do when the mains fails
MakerDuring the cutSource
StannahKeeps working on its batteries: fully charged, good for at least 15 to 20 trips up and down. A powered swivel seat has to be turned with its manual lever.Stannah batteries pageweb page
AcornWorks for several journeys, then the batteries lose their charge and the lift stops. It beeps for about a minute, then goes to sleep.Acorn 130 manualpp.18, 22
HandicareThe current 1100 manual: on lifts with the optional on/off switch, switch the lift's power off during a power cut in the building, to stop the batteries draining.Handicare 1100 manualp.3
BrooksIts batteries charge when the lift is not in use, so it keeps working in a power cut.Brooks questionsweb page
TKEA backup battery takes over and the lift still works.TKE questionsweb page

Why it beeps in a power cut

With no mains, the lift cannot charge, and most lifts announce that with the same beeping they use when parked off a charge point. Stannah's 260 guide says a beeping lift is one whose batteries are not being charged, and that it can carry on running on battery power for now; its first two checks are the wall switch and whether there has been a power cut (Stannah 260 guidep.25). An Acorn shows A1 and beeps, then after about a minute goes into sleep mode, beeping now and then; the 130 gives two beeps roughly every 40 seconds and the 180 a beep every 20 seconds. Using the controls wakes it. Stair lift beeping has every make's pattern.

Saving the battery while the power is off

Two makers say switching the lift off during an outage can protect the batteries. Handicare's current 1100 manual gives that instruction for lifts with the optional on/off switch. Stannah's battery-types page says that, only in a power cut, you can save battery power by turning off the isolator switch when you are not using the lift, and calls that an emergency measure, because a lift kept switched off does not charge properly (Stannah battery typesweb page). If you switch off, put a note on the lift so nobody forgets to switch it back on.

If someone is stuck on the lift during a power cut

If they are hurt or cannot get off safely, call 999. Otherwise use only the maker's own restart from the seat: see stuck on the stairs.

When the power comes back: what to check

  1. Switches back on. The wall socket or spur, and any switch you turned off on the lift: Stannah's master power switch, Acorn's battery isolation switch, Handicare's on/off switch.
  2. On its charge point. Wake the lift if it is asleep and send it to where it charges. The beeping should stop once it is charging.
  3. Let it recharge before relying on it. Acorn's 180 manual says that if the batteries have lost their charge because the mains was off or interrupted, let them recharge before using the lift (Acorn 180 manualp.11). With E7 showing, an Acorn will only go down until they have.
  4. Check the display. If it shows a code, look it up in the error code library.

Still not working after a long cut

A long enough outage can take batteries past the point of recovery. Acorn's manuals say that without a supply of power the batteries will eventually become too low to be recharged, and then have to be replaced by an engineer, which is chargeable and not covered by the manufacturer's warranty (Acorn 130 manualp.18). Stannah's sign of the same thing is a lift that will not charge at its usual charging point. If the lift is on charge with the power on and still will not work after a reasonable time, that is the engineer's point: see battery problems and battery replacement.

A lift that is old enough to have no batteries

Stannah notes that some older stair lifts are mains powered and have no batteries at all, so nothing on this page about charging applies to them. Check the lift's own guide to see which kind you have. The repair quote form at the foot of this page reaches SEO Dons Ltd, which replies by email.

Where this comes from

Each meaning, check and number above is taken from the documents listed here, opened on the maker's own website. Page numbers in the text are the numbers printed in each manual. How the makers' documents are checked.

Get a stair lift repair quote

For when the maker's manual says it is a job for an engineer. Give the make, the model and what the lift shows or does. Replies come by email, so this is not the way to get help for someone stuck on a lift now.

After you press send

  1. SEO Dons Ltd, which publishes Stairlift Support, receives what you send.
  2. Someone reads the make, the model and the fault, and replies by email.
  3. There is no obligation: asking does not commit you to any repair.
Add the model and the exact code, light or beep (optional)

Stairlift Support is published by SEO Dons Ltd, which has no engineers and no link to any stair lift maker. Answers come by email. Someone stuck on a stair lift who is hurt or in danger needs 999, not this form. How details are used: privacy notice.

Get a stair lift repair quote
Get a stair lift repair quote