Batteries and charging

How long do stairlift batteries last?

How long stairlift batteries last depends mostly on how the lift is looked after, and only two makers in this guide put a figure on it. Stannah says around 2 to 5 years on one of its pages and around 3 to 5 years on another; TKE says between 2 and 5 years, and longer with light use. Both say the same thing shortens battery life: a lift often left off its charge point. Acorn's and Handicare's manuals give no figure.

Last checked: , against the makers' own documents Published by SEO Dons Ltd

Battery life, as each maker states it

Stair lift battery life in the makers' own words
MakerStated lifeWhat shortens it, per the makerSource
StannahAround 2 to 5 years, depending on useA lift often left off its charge pointStannah batteries pageweb page
StannahAround 3 to 5 years, depending on useLeft off its charge point; the lift switched offStannah battery typesweb page
TKE (thyssenkrupp)Usually 2 to 5 years; can be longer with light useLeft off its charging pointTKE questionsweb page
AcornNo figure in the 130 or 180 manualPower left off: batteries become too low to rechargeAcorn 130 manualp.18
HandicareNo figure in the 1100, 1000 or Freecurve manualThe manuals say never to unplug the liftHandicare 1000 manualp.22

Stannah's two pages give different lower figures; both are shown as published.

How long do Stannah stairlift batteries last?

Stannah gives both answers above. Its troubleshooting page says around 2 to 5 years, and its battery-types page says its batteries generally last around 3 to 5 years; both add that it depends on use and on whether the lift is often left off its charge point (Stannah battery typesweb page). Stannah's lifts use two 12 volt, 7.4 amp-hour valve-regulated lead-acid batteries, or larger 12 amp-hour ones on a 260 with a long staircase and on heavy-duty lifts. Stannah says its engineers test the batteries at a service and tell owners when replacement is due.

How long do Acorn stairlift batteries last?

Acorn's user manuals do not say. What they do say is how batteries die early: a stair lift left without a power supply runs its batteries down, and if they become too low to be recharged, an engineer has to replace them, outside the manufacturer's warranty and at a charge (Acorn 130 manualp.18). The 130 manual adds that leaving the battery isolation switch off has the same effect, and that is not covered by the warranty either. So the Acorn answer to "how long" is in the owner's hands as much as anyone's.

What makes batteries last

  • Park it where it charges, every time. Stannah calls this the one thing owners really need to think about, and TKE and Acorn say the same.
  • Leave the power on. Stannah: do not turn off the power at the socket or spur. Acorn: the supply should be left permanently connected and switched on. Handicare: never remove the lift's plug.
  • Do not leave it switched off. Stannah's beeping page warns that a lift switched off, or unable to charge, needs new batteries sooner (Stannah beeping pageweb page).
  • Plan for absences. Stannah's guides say to switch off both the master power switch and the wall switch before a long time away, so the batteries are still charged on return (Stannah 600 guidep.9).

Signs they are near the end

Stannah's list is the clearest: the lift runs slower than its usual pace or slows as it climbs, stops after a short distance and then carries on, or will not charge at its usual charging point (Stannah batteries pageweb page). It says there is no alarm or flashing light when batteries run low. On lifts with codes, a low-battery code that keeps returning after full charges says the same thing: E7 on an Acorn, 7 on a Handicare 1100. Rule out the charging causes first on battery problems.

And in a power cut?

A separate question with a separate number. Stannah says fully charged batteries keep its lifts going for at least 15 to 20 trips up and down in a power cut; Acorn says several journeys. That is the charge, not the battery's life. See after a power cut.

Remote control batteries

The handsets have batteries of their own, with their own life: Stannah says about a year with average use, and Acorn recommends replacing them every year (Acorn 180 manualp.15). Unlike the lift's batteries, these are an owner's job: see remote not working.

When they need replacing

Replacing the lift's batteries is an engineer's job on every make here. Who does it, and what each maker says about cost and warranty, is on stair lift battery replacement. The repair quote form at the foot of this page reaches SEO Dons Ltd, which replies by email.

Where this comes from

Each meaning, check and number above is taken from the documents listed here, opened on the maker's own website. Page numbers in the text are the numbers printed in each manual. How the makers' documents are checked.

Get a stair lift repair quote

For when the maker's manual says it is a job for an engineer. Give the make, the model and what the lift shows or does. Replies come by email, so this is not the way to get help for someone stuck on a lift now.

After you press send

  1. SEO Dons Ltd, which publishes Stairlift Support, receives what you send.
  2. Someone reads the make, the model and the fault, and replies by email.
  3. There is no obligation: asking does not commit you to any repair.
Add the model and the exact code, light or beep (optional)

Stairlift Support is published by SEO Dons Ltd, which has no engineers and no link to any stair lift maker. Answers come by email. Someone stuck on a stair lift who is hurt or in danger needs 999, not this form. How details are used: privacy notice.

Get a stair lift repair quote